Perkins 24 kVA Diesel Standby Generator
3 Year Perkins Engine Warranty – The BEST that money can buy!
200 AMP Automatic Transfer Switch Included
$11,999.00
Perkins Engines Company Limited, a subsidiary of Caterpillar Inc., is a diesel engine manufacturer for several markets including marine and stationary power plant based in Peterborough, England, USA and China. Worldwide, an estimated one in five tractors is powered by a Perkins engine.
You are looking at perhaps the best diesel generator money can buy. This is a genuine Perkins powered generator. It is matched with a Leroy Somer Alternator and Automatic Voltage Regulator. Packaged in our weather proof canopy with simple to use generator controllers, automatic transfer switch and our exclusive wiring methods this generator is designed to outlast all others.
This generator can be run nonstop 24 hours a day 7 days a week, 365 days a year. It makes a perfect prime source of power. You only need to shut it down for normal routine maintenance such as an oil chance and refueling
Main Features
- Perkins Engine
- Leroy Somer Alternator
- 24 kVA / 20,000 Watts
- Weather proof Enclosure
- Internal Belly Fuel Tank
- 200 Amp Automatic Transfer Switch
- Leroy Somer Automatic Voltage Regulator
- Large Quiet Muffler

Perkins Engine
400 Series 404D-22G
- 23.9 kWm @ 1800 rev/min
- The 404D-22G ElectropaK is a powerful but quiet 2.2 litre naturally aspirated 4 cylinder compant package
Compact, Clean, Efficient Power
- Design features on the 400D range of ElectropaKs ensures clean rapid starting in all conditions whilst delivering impressive performance with low operating costs in a small, efficient package size
Lower Operating Costs
- The compact package Size makes Installation and transportation easier and more cost effective
- Operating and maintenance costs are reduced through excellent fuel and oil economy
- Service intervals are set at 500 hours as standard and Perkins provides comprehensive warranty cover for two years, with three years on major engine components. A low usage warranty package is also available
Long-term Power Solution
- The 400D range of ElectropaKs has been designed to fully comply with stringent EU and EPA emissions regulations, providing an emissions compliant power solution for the future
World-class Product Support
- Perkins is constantly researching, developing and investing in products and services. Total worldwide support is provided through a network of distributors and service outlets, providing access to over 50,000 parts and exchange units 24 hours a day, 365 days a year. This support is enhanced by TIPSS (The Integrated Parts and Service System). TIPSS enables customers to electronically specify and order parts as well as service 400 Series engines with online guides and service tools
Emissions statement
- Certified against the requirements of EU2007 (EU 97/68/EC Stage II) and EPA Interim Tier 4 (EPA 40 CFR Part 1039 Interim Tier 4) legislation for non-road mobile machinery, powered by constant speed engines
| Engine Speed | Type Of Operation | Typical Generator Output (Net) | Engine Power | ||||
| Gross | Net | ||||||
| kVA | kWe | kWm | bhp | kWm | bhp | ||
| 1500 | Prime Power | 20.0 | 16.0 | 18.7 | 25.1 | 18.4 | 24.6 |
| Standby Power | 22.1 | 17.7 | 20.6 | 27.6 | 20.3 | 27.2 | |
| 1800 | Prime Power | 24.0 | 19.2 | 22.0 | 29.5 | 21.6 | 29.0 |
| Standby Power | 26.6 | 21.3 | 24.3 | 32.6 | 23.9 | 32.1 | |
Air Inlet
- Mounted air filter
Fuel System
- Mechanically governed cassette type fuel injection pump
- Split element fuel filter
Lubrication System
- Wet steel sump with filler and dipstick
- Spin-on full-flow lub oil filter
Cooling System
- Thermostatically-controlled system with belt driven coolant pump and pusher fan
- Mounted radiator, piping and guards
Electrical Equipment
- 12 volt starter motor and 12 volt 65 amp alternator with DC output
- Oil pressure and coolant temperature switches
- 12 volt shut off solenoid energised to run
- Glow plug cold start aid and heater/starter switch
Flywheel and Housing
- 1500/1800 rev/min
- High inertia flywheel to SAE J620 Size 71/2 Heavy
- Flywheel housing SAE 4 Long
- 3000 rev/min
- High inertia flywheel to SAE J620 Size 71/2 Light
- Flywheel housing SAE 4 Short
Mountings
- Front and rear engine mounting bracket
Optional Equipment
- Workshop manual
- Parts book
Alternator / Generator

Model: Leroy Somer LSA 42.2 L9
LEROY-SOMER has a presence on the North-American continent through the extensive network of its sister company US Motors, which is also a subsidiary of the main group shareholder, Emerson.
These networks include a number of partners : distributors, service centers, design offices, engineering offices. Technical support material is specific to each product line and is produced in a number of languages.
Main specifications
- Alternator brushless with exciter
- SHUNT excitation with A.V.R R 250
- Class H insulation
- Dedicated single phase winding, 4 wires, 2/3 pitch
- Single bearing or two bearing arrangement
- Prime mover gas or diesel engine
- IP23 enclosure
COMPLIANT WITH INTERNATIONAL STANDARDS
LSA 42.2 / 43.2 / 44.2 alternators conform to the main international standards and regulations: IEC 60034, NEMA MG 1.22, ISO 8528/3, CSA, UL 1446. UL 1004B on request, etc. It can be integrated into a CE marked generator. LSA 42.2 / 43.2 / 44.2 are designed, manufactured and marketed in an ISO 9001 and ISO 14001 environment.
TOP OF THE RANGE ELECTRICAL PERFORMANCE
- Class H insulation
- Standard 4-wire re-connectable.
- Dedicated single phase windings, type M or M1, optimised for frequency 60Hz, voltage 240V and PF = 1 (15% derating for use at PF = 0,8) (PF = 1 corresponds to general use for single phase voltage).
- 4 lead stator allowing the re-connections bellow :
- 50 Hz : 230 V in series, 115 V in parallel
- 60 Hz : 240 V in series, 120 V in parallel (excepted for LSA 44.2 : only series)
- Total harmonic content < 4%.
EXCITATION AND REGULATION SYSTEM SUITED TO THE APPLICATION
- Voltage regulator accuracy +/- 0,5%.
PROTECTION SYSTEM SUITED TO THE ENVIRONMENT
- LSA 42.2 / 43.2 / 44.2 are IP 23.
- Standard winding protection for clean environments with relative humidity
- Options:
- Filters on air inlet and air outlet (IP 44).
- Winding protections for harsh environments and relative humidity greater than 95%.
- Space heaters.
- Thermal protection for winding.
REINFORCED MECHANICAL STRUCTURE USING FINITE ELEMENT MODELLING
- Compact and rigid assembly to better withstand generator vibrations.
- Steel frame
- Aluminum (LSA 42.2) or cast iron (LSA 43.2/44.2) flanges and shields.
- Twin-bearing and single-bearing versions designed to be suitable for engines on the market.
- Half-key balancing.
- Greased for life bearings (regreasable bearings optional)
ACCESSIBLE TERMINAL BOX PROPORTIONED FOR OPTIONAL EQUIPMENT
- Easy access to the voltage regulator and to the connections.
- 8 way terminal block for reconnecting voltage reconnection.
| Alternator Model LSA 42.2 – 4 Pole 50 Hz (1500 r.p.m) – 60 Hz (1800 r.p.m) | |
| Insulation class | H |
| Winding pitch – Code | 2/3 pitch – winding M (M1 for M7/L9 at 60 Hz) |
| Leads | 4 |
| Drip proof | IP 23 |
| Air flow | 0,15 / 0,18 m3/s |
| Excitation system | SHUNT |
| A.V.R. model | R 250 |
| Voltage regulation (*) | 0,5 % |
| Total harmonic TGH / THC (**) | < 4 % |
| Waveform : NEMA = TIF – (**) | < 50 |
| Wave form : I.E.C. = THF – (**) | < 2 % |
| Ratings 50 Hz – 1500 r.p.m. | Ratings 60 Hz – 1800 r.p.m. | |||||||
| kVA / kW – Power factor = 1 | kVA / kW – Power factor = 1 | |||||||
| Duty/Ambiant T | Continuous / 40 C | St. By. 40 C | St. By. 27 C | Continuous / 40 C | St. By. 40 C | St. By. 27 C | ||
| Class / T rise | H / 125 K | F / 105 K | H / 150 K | H / 163 K | H / 125 K | F / 105 K | H / 150 K | H / 163 K |
| 230 V | 230 V | 230 V | 230 V | 240 V | 240 V | 240 V | 240 V | |
| 115 V | 115 V | 115 V | 115 V | 120 V | 120 V | 120 V | 120 V | |
| LSA 42.2 L9 | 25 | 22.5 | 26 | 27 | 30 | 27 | 32 | 33 |
Generator Panel
The generator panel is easy view with the door closed through the window or open as you see here. It is easy to quickly see engine and alternator status with the indicator lights or gauges. Operation is monitored by a generator controller that takes care of automatic starting and stopping. Low oil, high temperature and some other fault conditions such as battery charging are also monitored.
Simple easy to read panel showing both the digital controller and its status lights as well as the voltage,
frequency, amp meters, water temperature, oil pressure, battery voltage and hour meter.
200 Amp Automatic Transfer Switch

Easy To Follow Electrical Wiring
Each and every wire has a numbered label on it. If you should ever need to service anything you or your service people can easily trace wires and follow wiring diagrams. Labor and trouble shooting are drastically reduced saving you time and money.
This is where you really see what makes Aurora Generator built products so much better then others. Every single wire is labeled and easily followed. Included wiring diagram is so easy for anyone to identify



Muffler
Perkins Engine Service is available around the world.