{"id":2335907151949,"title":"55 kW Diesel Generator | Bare Bones","handle":"55-kw-diesel-generator-bare-bones","description":"\u003ch1\u003eBare Bones | 55 kW Diesel Generator\u003c\/h1\u003e\n\u003ch2\u003eNothing Fancy, it just works!\u003c\/h2\u003e\n\u003cp\u003ePerkins Bare Bones Diesel Generators\u003c\/p\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e55,000 Watt | 1P | 120\/240 Volt or 74 kW | 3P 110-600 Volts\u003cbr\u003ePerkins Engine \u003ca href=\"https:\/\/www.auroragenerators.com\/collections\/diesel-engines\/products\/1104d-44tg1-perkins-engine-55-kwe\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e1104D-44TG1\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eMecc Alte ECP32-3L or Linz PRO18LG\/4 Alternator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e [TABS]\n\u003ch5\u003eGeneral Specifications\u003c\/h5\u003e\n\u003cp\u003eThis bare-bones generator is designed for the do-it-yourselfer. We did the hard part. We carefully aligned and mated the alternator to the engine. We torqued the stainless steel fasteners between the alternator flex plate and the engine flywheel. The housing was also fastened together using high-quality stainless steel, socket head cap screws.\u003c\/p\u003e\n\u003cp\u003eVibration isolators and hardware is included. \u003c\/p\u003e\n\u003cp\u003eThe muffler is included and can be mounted in a few directions to fit your needs better.\u003c\/p\u003e\n\u003cp\u003eWhat you have, is a world-class Perkins engine and alternator ready to mount and use for your own prime or standby power application.\u003c\/p\u003e\n\u003cp\u003eWhen you receive the generator, you will need to add engine oil and coolant. Connect the provided fuel lines to a diesel fuel supply and the battery cables to your battery. The wiring is left up to you, this is a DIY package.  All manuals can be downloaded from us online.\u003c\/p\u003e\n\u003cp\u003eAC Load Connections - Be sure to follow all electrical safety codes and consult with a professional as required. \u003c\/p\u003e\n\u003cp\u003eAURORA designs and builds diesel generators complete with auto-start controllers, fuel tanks, outdoor weather resistant and attenuated sound enclosures and more. This generator is just the bare bones for those who don't need anything else and want to save some money doing some work themselves.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: The image shown is just the alternator and engine for reference\u003c\/em\u003e\u003c\/p\u003e\n\u003ch5\u003eEngine\u003c\/h5\u003e\n\u003ctable class=\"aurora\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003ePerkins 1104D-44TG1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby Power Rating\u003c\/td\u003e\n\u003ctd\u003e55 kWe | 63 kWm | 1800 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAspiration\u003c\/td\u003e\n\u003ctd\u003eTurbocharged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCylinders\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplacement\u003c\/td\u003e\n\u003ctd\u003e4.41 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCycle\u003c\/td\u003e\n\u003ctd\u003e4 stroke\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRPM\u003c\/td\u003e\n\u003ctd\u003e1800 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompression Ratio\u003c\/td\u003e\n\u003ctd\u003e18.2:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustion System\u003c\/td\u003e\n\u003ctd\u003eDirect Injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGovernor Type\u003c\/td\u003e\n\u003ctd\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel System\u003c\/td\u003e\n\u003ctd\u003eDiesel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBore and Stroke\u003c\/td\u003e\n\u003ctd\u003e105mm x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling System\u003c\/td\u003e\n\u003ctd\u003eWater Cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoolant Capacity\u003c\/td\u003e\n\u003ctd\u003e13.2 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil Capacity\u003c\/td\u003e\n\u003ctd\u003e8.4 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarter\u003c\/td\u003e\n\u003ctd\u003e12 Volts \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil and Filter Changes\u003c\/td\u003e\n\u003ctd\u003e500 Hours depending on load factor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Alternator\u003c\/td\u003e\n\u003ctd\u003e65 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling System\u003c\/td\u003e\n\u003ctd\u003eRadiator with belt-driven pusher fan and guards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarting Aid\u003c\/td\u003e\n\u003ctd\u003eGlow Plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions L x W x H\u003c\/td\u003e\n\u003ctd\u003e1238 mm x 967 mm x 637 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlywheel\u003c\/td\u003e\n\u003ctd\u003eSAE J620  Size 10\/11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eSAE J620 SAE 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Inlet\u003c\/td\u003e\n\u003ctd\u003eMounted Air filter and turbocharger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel Consumption\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby\u003c\/td\u003e\n\u003ctd\u003e18.7 l\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrime Power\u003c\/td\u003e\n\u003ctd\u003e16.6 l\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e75% Prime Power\u003c\/td\u003e\n\u003ctd\u003e12.8 l\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50% Prime Power\u003c\/td\u003e\n\u003ctd\u003e9.0 l\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25% Prime Power\u003c\/td\u003e\n\u003ctd\u003e5.2 l\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/div\u003e\n\u003ca href=\"https:\/\/www.perkins.com\/en_GB\/products\/new\/perkins\/electric-power-generation\/diesel\/1000002666.html\" target=\"_blank\" rel=\"noopener noreferrer\"\u003ePerkins\u003c\/a\u003e\u003cspan\u003e Engine Warranty\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/div\u003e\n\u003cspan\u003e2 Year 3000 Hour - 5 Year Optional\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eAlternator\u003c\/h5\u003e\n\u003cp\u003eAurora industrial class alternators are highly reliable and produce clean, stable power even in harsh conditions. Automatic Voltage Regulated to 0.5% precision. The alternator is brushless and requires no maintenance. The generator head is directly driven by a heavy engine flywheel. The large rotating mass helps to reduce fluctuations in power when heavy loads are applied.\u003c\/p\u003e\n\u003ctable class=\"aurora\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinz PRO18L G\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power 60 Hz. kVA\u003c\/td\u003e\n\u003ctd\u003e72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power Factor \u003c\/td\u003e\n\u003ctd\u003e0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Temperature\u003c\/td\u003e\n\u003ctd\u003e40 c\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl System\u003c\/td\u003e\n\u003ctd\u003eself-excited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution\u003c\/td\u003e\n\u003ctd\u003ebrushless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulation Type\u003c\/td\u003e\n\u003ctd\u003eAVR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Type\u003c\/td\u003e\n\u003ctd\u003eClass H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eIP23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Over Speed rpm\u003c\/td\u003e\n\u003ctd\u003e2250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload\u003c\/td\u003e\n\u003ctd\u003e110% of rated power for one hour in a cycle of 6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Flow Requirement \n\u003cdiv\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/div\u003e\nm3 \/min \u003c\/td\u003e\n\u003ctd\u003e14 at 60 Hz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e*Subject to change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eOr \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.auroragenerators.com\/collections\/newest-products\/products\/55-kw-alternator-1p-120-240-volts-mecc-alte-ecp32-3l\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eMecc Alte ECP32 Seen Here\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e[\/TABS]\u003c\/p\u003e","published_at":"2018-12-15T20:20:14-05:00","created_at":"2018-12-15T16:42:27-05:00","vendor":"Aurora Generators","type":"Generator","tags":["Bare Bones","Perkins"],"price":1262500,"price_min":1262500,"price_max":1262500,"available":true,"price_varies":false,"compare_at_price":1450000,"compare_at_price_min":1450000,"compare_at_price_max":1450000,"compare_at_price_varies":false,"variants":[{"id":20949584117837,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AGi55-1-240-BB","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"55 kW Diesel Generator | Bare Bones","public_title":null,"options":["Default Title"],"price":1262500,"weight":408233,"compare_at_price":1450000,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/1262\/8579\/products\/1104D-44TG.jpg?v=1544910483","\/\/cdn.shopify.com\/s\/files\/1\/1262\/8579\/products\/linz_2.png?v=1544910515","\/\/cdn.shopify.com\/s\/files\/1\/1262\/8579\/products\/SMU270.png?v=1544910546"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/1262\/8579\/products\/1104D-44TG.jpg?v=1544910483","options":["Title"],"content":"\u003ch1\u003eBare Bones | 55 kW Diesel Generator\u003c\/h1\u003e\n\u003ch2\u003eNothing Fancy, it just works!\u003c\/h2\u003e\n\u003cp\u003ePerkins Bare Bones Diesel Generators\u003c\/p\u003e\n\u003ch2\u003eGeneral Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e55,000 Watt | 1P | 120\/240 Volt or 74 kW | 3P 110-600 Volts\u003cbr\u003ePerkins Engine \u003ca href=\"https:\/\/www.auroragenerators.com\/collections\/diesel-engines\/products\/1104d-44tg1-perkins-engine-55-kwe\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e1104D-44TG1\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eMecc Alte ECP32-3L or Linz PRO18LG\/4 Alternator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e [TABS]\n\u003ch5\u003eGeneral Specifications\u003c\/h5\u003e\n\u003cp\u003eThis bare-bones generator is designed for the do-it-yourselfer. We did the hard part. We carefully aligned and mated the alternator to the engine. We torqued the stainless steel fasteners between the alternator flex plate and the engine flywheel. The housing was also fastened together using high-quality stainless steel, socket head cap screws.\u003c\/p\u003e\n\u003cp\u003eVibration isolators and hardware is included. \u003c\/p\u003e\n\u003cp\u003eThe muffler is included and can be mounted in a few directions to fit your needs better.\u003c\/p\u003e\n\u003cp\u003eWhat you have, is a world-class Perkins engine and alternator ready to mount and use for your own prime or standby power application.\u003c\/p\u003e\n\u003cp\u003eWhen you receive the generator, you will need to add engine oil and coolant. Connect the provided fuel lines to a diesel fuel supply and the battery cables to your battery. The wiring is left up to you, this is a DIY package.  All manuals can be downloaded from us online.\u003c\/p\u003e\n\u003cp\u003eAC Load Connections - Be sure to follow all electrical safety codes and consult with a professional as required. \u003c\/p\u003e\n\u003cp\u003eAURORA designs and builds diesel generators complete with auto-start controllers, fuel tanks, outdoor weather resistant and attenuated sound enclosures and more. This generator is just the bare bones for those who don't need anything else and want to save some money doing some work themselves.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: The image shown is just the alternator and engine for reference\u003c\/em\u003e\u003c\/p\u003e\n\u003ch5\u003eEngine\u003c\/h5\u003e\n\u003ctable class=\"aurora\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003ePerkins 1104D-44TG1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby Power Rating\u003c\/td\u003e\n\u003ctd\u003e55 kWe | 63 kWm | 1800 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAspiration\u003c\/td\u003e\n\u003ctd\u003eTurbocharged\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCylinders\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplacement\u003c\/td\u003e\n\u003ctd\u003e4.41 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCycle\u003c\/td\u003e\n\u003ctd\u003e4 stroke\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRPM\u003c\/td\u003e\n\u003ctd\u003e1800 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompression Ratio\u003c\/td\u003e\n\u003ctd\u003e18.2:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustion System\u003c\/td\u003e\n\u003ctd\u003eDirect Injection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGovernor Type\u003c\/td\u003e\n\u003ctd\u003eElectronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel System\u003c\/td\u003e\n\u003ctd\u003eDiesel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBore and Stroke\u003c\/td\u003e\n\u003ctd\u003e105mm x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling System\u003c\/td\u003e\n\u003ctd\u003eWater Cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoolant Capacity\u003c\/td\u003e\n\u003ctd\u003e13.2 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil Capacity\u003c\/td\u003e\n\u003ctd\u003e8.4 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarter\u003c\/td\u003e\n\u003ctd\u003e12 Volts \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil and Filter Changes\u003c\/td\u003e\n\u003ctd\u003e500 Hours depending on load factor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Alternator\u003c\/td\u003e\n\u003ctd\u003e65 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling System\u003c\/td\u003e\n\u003ctd\u003eRadiator with belt-driven pusher fan and guards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarting Aid\u003c\/td\u003e\n\u003ctd\u003eGlow Plugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions L x W x H\u003c\/td\u003e\n\u003ctd\u003e1238 mm x 967 mm x 637 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlywheel\u003c\/td\u003e\n\u003ctd\u003eSAE J620  Size 10\/11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eSAE J620 SAE 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Inlet\u003c\/td\u003e\n\u003ctd\u003eMounted Air filter and turbocharger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuel Consumption\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby\u003c\/td\u003e\n\u003ctd\u003e18.7 l\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrime Power\u003c\/td\u003e\n\u003ctd\u003e16.6 l\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e75% Prime Power\u003c\/td\u003e\n\u003ctd\u003e12.8 l\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50% Prime Power\u003c\/td\u003e\n\u003ctd\u003e9.0 l\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25% Prime Power\u003c\/td\u003e\n\u003ctd\u003e5.2 l\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/div\u003e\n\u003ca href=\"https:\/\/www.perkins.com\/en_GB\/products\/new\/perkins\/electric-power-generation\/diesel\/1000002666.html\" target=\"_blank\" rel=\"noopener noreferrer\"\u003ePerkins\u003c\/a\u003e\u003cspan\u003e Engine Warranty\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/div\u003e\n\u003cspan\u003e2 Year 3000 Hour - 5 Year Optional\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eAlternator\u003c\/h5\u003e\n\u003cp\u003eAurora industrial class alternators are highly reliable and produce clean, stable power even in harsh conditions. Automatic Voltage Regulated to 0.5% precision. The alternator is brushless and requires no maintenance. The generator head is directly driven by a heavy engine flywheel. The large rotating mass helps to reduce fluctuations in power when heavy loads are applied.\u003c\/p\u003e\n\u003ctable class=\"aurora\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinz PRO18L G\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power 60 Hz. kVA\u003c\/td\u003e\n\u003ctd\u003e72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power Factor \u003c\/td\u003e\n\u003ctd\u003e0.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Temperature\u003c\/td\u003e\n\u003ctd\u003e40 c\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl System\u003c\/td\u003e\n\u003ctd\u003eself-excited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution\u003c\/td\u003e\n\u003ctd\u003ebrushless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulation Type\u003c\/td\u003e\n\u003ctd\u003eAVR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Type\u003c\/td\u003e\n\u003ctd\u003eClass H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eIP23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Over Speed rpm\u003c\/td\u003e\n\u003ctd\u003e2250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload\u003c\/td\u003e\n\u003ctd\u003e110% of rated power for one hour in a cycle of 6 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Flow Requirement \n\u003cdiv\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/div\u003e\nm3 \/min \u003c\/td\u003e\n\u003ctd\u003e14 at 60 Hz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e*Subject to change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eOr \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.auroragenerators.com\/collections\/newest-products\/products\/55-kw-alternator-1p-120-240-volts-mecc-alte-ecp32-3l\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eMecc Alte ECP32 Seen Here\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e[\/TABS]\u003c\/p\u003e"}

Bare Bones | 55 kW Diesel Generator

Nothing Fancy, it just works!

Perkins Bare Bones Diesel Generators

General Specifications

  • 55,000 Watt | 1P | 120/240 Volt or 74 kW | 3P 110-600 Volts
    Perkins Engine 1104D-44TG1
  • Mecc Alte ECP32-3L or Linz PRO18LG/4 Alternator
$ 12,625.00 USD $ 14,500.00 USD
Maximum quantity available reached.
Sku: AGi55-1-240-BB
UPC:

This bare-bones generator is designed for the do-it-yourselfer. We did the hard part. We carefully aligned and mated the alternator to the engine. We torqued the stainless steel fasteners between the alternator flex plate and the engine flywheel. The housing was also fastened together using high-quality stainless steel, socket head cap screws.

Vibration isolators and hardware is included. 

The muffler is included and can be mounted in a few directions to fit your needs better.

What you have, is a world-class Perkins engine and alternator ready to mount and use for your own prime or standby power application.

When you receive the generator, you will need to add engine oil and coolant. Connect the provided fuel lines to a diesel fuel supply and the battery cables to your battery. The wiring is left up to you, this is a DIY package.  All manuals can be downloaded from us online.

AC Load Connections - Be sure to follow all electrical safety codes and consult with a professional as required. 

AURORA designs and builds diesel generators complete with auto-start controllers, fuel tanks, outdoor weather resistant and attenuated sound enclosures and more. This generator is just the bare bones for those who don't need anything else and want to save some money doing some work themselves.

Note: The image shown is just the alternator and engine for reference

Model Number Perkins 1104D-44TG1
Standby Power Rating 55 kWe | 63 kWm | 1800 RPM
Aspiration Turbocharged
Cylinders 4
Displacement 4.41 litres
Cycle 4 stroke
RPM 1800 RPM
Compression Ratio 18.2:1
Combustion System Direct Injection
Governor Type Electronic
Fuel System Diesel
Bore and Stroke 105mm x 127 mm
Cooling System Water Cooled
Coolant Capacity 13.2 litres
Oil Capacity 8.4 litres
Starter 12 Volts 
Oil and Filter Changes 500 Hours depending on load factor.
Battery Alternator 65 Amps
Cooling System Radiator with belt-driven pusher fan and guards
Starting Aid Glow Plugs
Dimensions L x W x H 1238 mm x 967 mm x 637 mm
Flywheel SAE J620  Size 10/11
Housing SAE J620 SAE 3
Air Inlet Mounted Air filter and turbocharger
Fuel Consumption
Standby 18.7 l/hr
Prime Power 16.6 l/hr
75% Prime Power 12.8 l/hr
50% Prime Power 9.0 l/hr
25% Prime Power 5.2 l/hr
Perkins Engine Warranty
2 Year 3000 Hour - 5 Year Optional

Aurora industrial class alternators are highly reliable and produce clean, stable power even in harsh conditions. Automatic Voltage Regulated to 0.5% precision. The alternator is brushless and requires no maintenance. The generator head is directly driven by a heavy engine flywheel. The large rotating mass helps to reduce fluctuations in power when heavy loads are applied.

Linz PRO18L G/4
Rated Power 60 Hz. kVA 72
Rated Power Factor  0.8
Nominal Temperature 40 c
Control System self-excited
Execution brushless
Regulation Type AVR
Insulation Type Class H
Protection IP23
Maximum Over Speed rpm 2250
Overload 110% of rated power for one hour in a cycle of 6 hours
Air Flow Requirement 
m3 /min 
14 at 60 Hz.
*Subject to change

Or 

Mecc Alte ECP32 Seen Here