Menu
Cart 0

8,000 Watt Diesel Generator

Model: AGi7P-Basic

Small, Simple, Clean and  Inexpensive

You can find this little two cylinder, liquid cooled Perkins and Caterpillar engine on many transport trucks.  It is often used for auxiliary power generation.  Refrigeration units on shipping containers also use them.  They are a robust engine designed to work hard for thousand of hours. They often outlast much larger slow turning diesel engines.  In fact, they carry the same warranty and  500hr oil change Interval.   It does not matter if you use it full-time or part-time or what your application is. Includes many of our standard equipped features and components such as Dynagen TG350 generator controller, main circuit breaker, muffler and coolant expansion bottle.

We have seen a few others offer products using the same engine but, nobody else does so without using belts or gears.  The alternator we use on this unit is direct flywheel driven just like on much larger generators.  Same high-quality power generation without requiring any maintenance. 

 

 

Model: AGi8P
Standby Power Rating: 8,000 Watts
Prime Power Rating: 6,000 Watts
Voltage 120 Volts @ 60 Amps
240 Volts @ 30 Amps
FEATURES
    • Engine - Small engine with the same exceptional performance and long life as the larger Perkins engines. Liquid cooled, two cylinder, 0.5-liter engine is suitable for both prime and standby power use. Enjoy fewer oil, air and fuel filter changes (every 500 hours depending on load factor). The low fuel consumption and ultra-compact engine offers all the customer benefits experienced from larger engine sizes. The engine has a proven record for hard working reliability in transport truck auxiliary power units to re
    • Generator Alternator - Aurora industrial class alternators are highly reliable and produce clean, stable power even in harsh conditions. Automatic Voltage Regulated to 0.5% precision. The alternator is brushless and requires no maintenance. The generator head is directly driven by a heavy engine flywheel. The large rotating mass helps to reduce fluctuations in power when heavy loads are applied.
    • Digital Generator - Clear generator instrumentation, protection, and control. 150 event logging, fuel level display and alarm, maintenance and exercise clock, and much more. The controller is built to withstand severe duty, extreme shock, and vibration. Easy to use and configure via front panel buttons. Can be used manually or with fully automatic starting with a transfer switch or wireless remote control. Accepts additional customer sensors and switched outputs.
Auto Start Generator Controller by DynaGen
Rear View of the DynaGen TG410 Generator Controller
    • Preheating & Post-heating- Pre and Post glow plug heating phases can be used in this generator. Preheating helps with the initial starting. Post-heating is used after the engine has started to help reduce false starts, rough idling, lower start-up emissions and warm up your engine faster. False starts are detected, and automatic recovery will restart if necessary. If required, this feature makes automatic starting simple.
    • Maintenance and Exercise Clock - It is easy to lose track of how long your generator has been running without it. The maintenance clock keeps track of your run time and is set to remind you when it is time to do an oil change. The exercise clock is also programmable as is the low battery voltage detection that can also trigger an exercise cycle if desired.
    • Engine Warranty - Perkins engines come with a two-year or 3,000-hour warranty
    • Generator Warranty - Aurora Generators come with a five-year limited warranty.
    • Beyond The Standard Engine Warranty - There is also an option to buy a Perkins Platinum Protection policy to cover you beyond the standard warranty period. Up to 100% components covered, transfer coverage to a new owner adding value to your generator if you wish to sell it, and you can buy the extended coverage anytime before your standard warranty coverage expires.
General Specifications  
Model AGi7P-Basic
Type Diesel
Power 8 kW Standby Generator
60 Hz., 3600 RPM Liquid Cooled
Single Phase, 1.0 Power Factor
Automatic Voltage Regulated
120 Volt - 60 Amps
240 Volt - 30 Amps
Sound Level  
Dimensions L x W x H 41”x23”x 38”
Weight 340 lbs
Country of Origin Made in Canada
Approvals CSA SPE-1000
Generator Controller  
Model TG350
Operating Voltage 5.5 to 38VDC continuous.
Cranking dropouts to 0VDC
for 50mS, also meets SAEJ1113-11
Standby Current Draw 50 MA
Protection Reverse battery protected & overload
Operating Temperature -40c - + 70c (-40 - +158F)
Vibration and Shock Meets or exceeds SAEJ1455
Electromagnetic Compatibility Meets or exceeds MIL-STD-461E Conducted Emissions
Configurable Switched Inputs 5
Configurable Switched Outputs 4
Warranty 5 Years

 

Engine Specifications  
Make/Model Perkins 402D-05G
Glow Plugs Included
Engine Speed 3600
Number of Cylinders 2
Aspiration Naturally Aspirated
Combustion System Indirect Injection
Compression Ratio 23.5:1
Bore and Stroke 67mm X 72mm (2.6"x2.8")
Displacement 0.51 L (31in³)
Cooling System Water Cooled
Coolant Capacity 1.1 L (0.3 gal US)
Oil Capacity 2.0 L (0.5 gal US)
Oil and Filter Changes 500 Hours depending on load factor.
Starter 12 Volt
Alternator 14 Amp
Starter Battery 540 CCA (Not Included)
Perkins Engine Warranty 2 Year 3000 Hour - 5 Year Optional

 

Alternator  
Model SMF162C
Type Brushless Automatic Voltage Regulated
Voltage Regulation ±1.0%
Rated Output 240 Volt Single Phase 12,500 Watts
Insulation Class H
Warranty 5 Years

DynaGen Generator Controller

 

DynaGen TG350 Generator Controller 

The DynaGen TOUGH series controller is designed to provide complete control, protection, and engine instrumentation. The controller is pre-configured and ready to use.  The simple press of a button is all that is needed to start or stop the generator.  Two wire remote start is a normal function so you can connect it or control it from another system.   Making any changes is easy.  By using the menu-driven front panel buttons or free PC configurator software you can have complete control of all functions and features the controller offers. 

Monitoring and Display 

  • Oil Pressure
  • Engine Temperature
  • Fuel Level
  • Oil Level
  • Hour Meter
  • RPM
  • Real time clock display with time/date
  • Battery Voltage
  • J1939 DTC codes with custom text
  • Two customer defined parameters (temperature, pressure, voltage, levels)
  • DPF and DEF status icons
  • 3-Phase AC Volts, Amps and Hz (for generators)

Features and Functions:

  • Modbus port with galvanic isolation to connect remote annunciators and internet monitoring devices
  • SAE J1939 CANbus Protocol
  • RPM via J1939, Magnetic pick-up, or Generator
  • Speed control offset adjustment for electronic engines
  • Auto start on Low Battery and other sensors
  • Front panel trim feature for sensor adjustment
  • Maintenance counter
  • Exerciser Clock
  • 150 Event Log
  • Conformally coated for protection against moisture and contaminants
  • Gasket for water ingress protection
  • Free PC Configurator Software
  • Fast and rugged installation clips
  • Passcode protected
  • Automatic shutdowns and warnings
  • Manual and remote start
  • Momentary start/stop inputs
  • Pre-heat and many configurable timers
  • Accepts common senders (VDO, Datcon, Murphy, and more)
  • Custom senders configurable with PC software
  • 5-year warranty

 

 

 

 

FRONT PANEL OR PC CONFIGURABLE

The TOUGH series can be programmed manually via front panel buttons or with our easy-to-use PC configurator software that provides customization of screen messages, sender selections, control settings, and much more. The PC configurator uses a standard USB cable with no special programmer required.

 

 

Operating Voltage

  • 5.5 to 38VDC continuous. Cranking dropouts to 0VDC for 50mS, also meets SAE J1113-11
  • Standby Current Draw: 60mA @ 12VDC, 38mA @ 24VDC
  • Reverse battery protected
  • Surge withstand & Load Dump: SAE J1113-11

Operating Temperature

  • Controller Function: -40 to +70˚C
  • Display Screen Viewing: -20 to +70˚C

Vibration & Shock

  • Meets or exceeds SAE J1455

Electromagnetic Compatibility

  • Meets or exceeds MIL-STD-461E 
    Conducted Emissions

Physical

  • Dimensions: 4.17”H x 6.5”W x 1.38”D
  • Weight: 0.83 lb

Speed Sensing

  • Via J1939 bus, Magnetic pick-up, or Generator

Inputs

  • AC Voltage Sensing (inputs for auto selection)
    • Single-phase 2 and 3-wire
    • Delta 3 and 4-wire
    • Wye 2, 3, and 4-wire
    • Max 600vac* (direct connection)
      true RMS, +/- 1% of full scale
  • Current Sensing
    • Accepts 5A Secondary CTs
    • +/- 2% of full scale
  • Fixed Sensor Inputs:
    • 0-7500Ω Engine Temperature sender
    • 0-750Ω Senders or switches**
  • Universal Sensor Inputs (Pressure, Temperature, Level, Volts or Amps.):
    • 0-7500Ω Senders, 4-20ma, 0-5V or switch**
    • 0-750Ω Senders

*for 600vac systems use a step-down transformer or centre tap.

  • Configurable Switched Inputs with programmble text
    • Auto detect close to +Bat or Gnd

Electronic Engine Support:

  • Standard J1939 Engines (Tier II, III & IV)
  • Support for Volvo, John Deere, Cummins, GM PSI, Yanmar, ISUZU*

*Consult factory for updates.

Outputs (includes fuel/crank)

  • Switched Outputs - 1A Max UL pilot duty:
    • Switched to +Battery
    • Short circuit & overload protected

Communications

  • SAE J1939
    • Tier 2, 3, 4i, and 4f engines
    • Address settings for both the controller and the engine ECM
  • USB
    • PC Configurator Connection
    • High retention socket accepts standard USB cable
  • Modbus
    • RTU slave mode
    • RS 485 port (9600, 19200, 38400, 57600 baud)
    • Galvanic isolation

8,000 Watt Diesel Generator - Simple Design

  • $5,370.00


If you are not sure what you need, contact us!
We can help. 1-877-510-6807

Selected Options: $0.00

Customer Reviews

Based on 3 reviews Write a review

We Also Recommend