20 kW Towable Mobile Diesel Generator

  • SKU # AGi20PM



AGi20PM | 2.2 L | 20 kW

TOWABLE DIESEL GENERATOR

STANDBY POWER RATING
20 KW , 20 KVA , 60 HZ.

PRIME POWER RATING
18 KW, 18 KVA, 60 HZ.

Custom Branding and Color Available 

Request A Quote


GENERAL SPECIFICATIONS 

 

 Model AGi20PM
Power 20 kW Standby
18 kW Prime
Type Diesel 
Engine Perkins  | 404D-22G | 2.2L | 4 Cylinder 
Power Outlets 2 - 120 Volt | 20 Amp | Duplex | 5-20R
2 - 120 Volt | 30 Amp | Twistlock | L6-30R
1 - 120 / 250 Volt | 30 Amp | Twistlock | L14-30
1 - 120 / 240 Volt |50 Amp | Twistlock | C6369
Alternator Single Phase | 120/240 Volt | 1 Phase | Brushless | AVR
Enclosure Sound Attenuated, Weather Resistant
Trailer 3,500 lb | Single Axle
Instrumentation  Illuminated Auto-Start Controller | DynaGen TG410
Generator Dimensions 76” x 35” x 46”
Trailer Dimensions 10.6’ x 4.7’
Generator Weight 2100 lbs
Approvals CSA / EPA
CAD Drawings PDF 2D Drawings
Specifications PDF Specifications

 


 

STANDARD FEATURES

MOBILE / TOWABLE GENERATOR

  • Enclosed silenced generator
  • Powered by Perkins engines
  • All stainless steel fasteners
  • Large capacity fuel tank
  • Heavy duty trailer
  • Made In Canada
  • Customizable electrical panel
  • Reduced maintenance costs

ENGINE

  • Exhaust Silencer
  • Oil pressure switch
  • Oil pressure sensor
  • Coolant temperature switch
  • Coolant temperature sensor
  • Coolant level sensor
  • EZ-Oil drain valve
  • Primary fuel filter
  • Fuel/water separator

COOLING SYSTEM

  • Factory-installed radiator
  • 50/50 ethylene glycol antifreeze
  • 120 VAC engine block coolant heater

ENGINE ELECTRICAL SYSTEM

  • Starter battery
  • Battery charging alternator
  • Battery cables
  • Battery tray
  • Solenoid activated starter motor
  • Complete engine instrumentation

ALTERNATOR SYSTEM

  • UL / CSA approved
  • Brushless excitation
  • Sealed bearings
  • Class H insulation
  • Voltage regulator
  • Main circuit breaker

GENERATOR CONSTRUCTION

  • Steel powder coated base frame assembly
  • All stainless steel fasteners
  • Vibration Isolation

ENCLOSURE

  • Sound attenuated, weather resistant
  • Galvannealed steel canopy  
  • Powder coat finish
  • Stainless steel fasteners
  • High-performance sound-absorbing material
  • Fully lockable enclosure
  • Weather stripping around doors
  • Weather resistant construction
  • Stamped air-intake louvers or vents
  • Sound attenuated insulation - 65 dB(A)  @23 feet

FUEL TANK

  • Internal fuel-tank sub-base diesel fuel tank
  • Powder coated steel construction, UL Listed
  • Direct readable fuel gauge
  • Controller monitored electronic gauge
  • Sensors, vents, valves

 


CONTROLLERDynaGen Generator Controller

FEATURES

  • Designed for harsh conditions with extreme shock and vibration
  • Easy to understand display messages. (no codes)
  • Automatic start/stop control when used with a transfer switch or remote
  • Clear generator instrumentation, protection and control. Includes battery voltage, AC ammeter, oil pressure, engine temperature, fuel level, fuel leak, hour meter, tachometer, frequency, voltage, coolant level, service clock, exerciser preheat, postheat, 150 event log, load balance, emergency shut-down monitors
  • CANBUS engine control
  • Field programmable settings (password protected)
  • Programmable setpoint warnings, alarms levels, and sensor trim feature.
  • Programmable low battery auto start / exercise
  • 2-Wire start compatible  
  • Computer programmable via USB Port
  • Uses standard automotive cube relays
  • 5 Year Manufacturer Warranty

CONTROLLER SPECIFICATIONS

Controller Specifications
Model DynaGen TG410
Operating Voltage 5.5 to 38 Volts DC
Cranking dropouts to 0 VDC for 50 mS  Also meets SAEJ113-11

Standby current draw

50 ma
Protection Reverse battery and overload protected
Operating Temperature -40c - 70c (-40 - +150 F)

Vibration and Shock

SAEJ1455
Electromagnetic Compatibility Meets or exceeds MIL-STD-461E Conducted Emissions
Configurable Switched Inputs 5
Configurable Switched Outputs 4
Warranty 5 Years
Specifications
User Manual

 


POWER PANEL

Generator Panel

  • 2 x 120 Volt duplex receptacles
  • 2 x 120/240 locking receptacle L14-30
  • 4 x USB power 4.2A
  • Emergency stop / Lockout key switch
  • Main breaker
  • Load terminal connections
  • Ground terminal block
  • Alarm and run signal out
  • Remote monitoring and control (Optional)

OPTIONS

ENGINE OPTIONS

  • Battery charger 1 Amp
  • Battery charger 4 Amp
  • Block heater 400 Watt
  • HOTstart circulation pump 1000 Watt
  • Battery warmer
  • Spare filters
  • Ambient air heater | Anti-condensation heater

CIRCUIT BREAKER OPTIONS

  • Shunt trip
  • Auxiliary contact

GENERATOR SET

  • Remote monitoring and control (cellular based)
  • Load center
  • Coolant heater ball valves
  • Fluid containment pans

ENCLOSURE OPTIONS

  • Ambient air heater
  • 12 VDC Enclosure Lighting Kit
  • 120 VAC Enclosure Lighting Kit

CONTROL SYSTEM

  • E-Stop | Red Mushroom-Type
  • Cellular remote monitoring and control
  • Modbus terminal Block
  • Canbus terminal Block
  • Alarm signal block
  • Engine run signal block
  • ATS signal block
  • Battery disconnect switch

ENGINE SPECIFICATIONS

ENGINE SPECIFICATIONS
Make Perkins
Model 404D-22G
Number of cylinders 4
Cycle Four stroke
Induction system Naturally aspirated
Compression Ratio 23,3:1
Bore 84 mm
Stroke 100 mm
Cubic capacity 2.216 litres
Direction of rotation Anti Clockwise when viewed from flywheel
Firing order 1,3,4,2
Estimated total weight of Electropak (dry) 242 kg
Maintenance Oil Changes 500 Hours
ENGINE PERFORMANCE
Note: All data based on operation to ISO 3046-1:2002 standard reference conditions
Speed variation at constant load ± 0,5%
Test conditions - air temperature 25 °C
Test conditions - barometric pressure 100 kPa
Relative humidity 31.5%
Air inlet restriction at maximum power (nominal) 3 kPa
Exhaust back pressure at maximum power (nominal) 10.2 kPa
Fuel temperature (inlet pump) 40 °C
Sound Level
Average sound pressure level for bare engine - WITHOUT inlet and exhaust or canopy enclosure at 1 metre
79 dB(A)
All ratings certified to within ± 5%

If the engine is to operate in ambient conditions other than those of the test conditions, suitable adjustments must be made for these changes. For full details, contact Perkins Technical Service Department. Emissions Statement: Certified against the requirements of EU2007 (EU97/68/EC Stage II) and EPA Interim Tier 4 (EPA 40 CFR Part 1039 Interim Tier 4) legislation for nonroad mobile machinery, powered by constant speed engines

 


ALTERNATOR SPECIFICATIONS

Linz Alternator | Diesel Generator

Model SM180C
Type Brushless
Prime Power 8.0 kW
Standby Power 20.0 kW
Efficiency 84.3%
Approvals I EC60034,NEMA MG1-32,IS08528,CSA C22.2-100,VDE 0530,GB755
Insulation Class H
Voltage Regulation AVR Model VR301 ± 0.5%
THD No load<1.5%
Altitude <=1000m
Winding Pitch 2/3
Protection IP23
Weight 124 kG | 273.4 lb
4 Pole Alternator Brushless with AVR
Voltage Regulation ±0.5%
Rated Output 120/240 Volt | Single Phase 55 kW 69 kVA
Insulation Class H
Warranty 5 Years

Ratings based on 60Hz / 1800RPM / 40℃ / PF 0.8

 


POWER RATINGS

Single-Phase 120/240 VAC @1.0pf 83 Amps
Three-Phase 120/208 VAC @0.8pf 69 Amps
Three-Phase 277/480 VAC @0.8pf 30 Amps
Three-Phase 346/600 VAC @0.8pf 24 Amps

 


 

FUEL CONSUMPTION RATES

Prime power rating is the maximum power accessible at the variable load for an unlimited number of hours per year in a variable load setting Standby Power rating is the maximum power available. No overload is permitted. Average variable load factor is 70%
Continuous Power  is the non-varying load for an unlimited number of hours.

Standby Power 20 kW 6.9 L (1.82 gallon) / Hour
Prime Power 18 kW 6.2 L (1.64 gallon) / Hour
75% Prime Power 4.8 L (1.27 gallon) / Hour
50% Prime Power 3.5 L (0.93 gallon) / Hour

 


 

FUEL TANK

Type Single or Double Wall Diesel Sub-Base Tank
Design Steel Construction with Secondary Containment Rapture Basin Design |Heavy Duty Side Channels
Approval UL-142 / ULC-S601 Steel Construction (CSA B139 Optional)
Finish Powder Coat Black
Vent/Fill/Alarm UL/NFPA Sized Emergency Vents, 2” NPT
2” Normal Vent
Low Fuel Level Alarm Switch
Manual Locking Fill Cap
Visual Fuel Level Gauge
Fuel in basin alarm switch
Weight 385 lb
Other Lifting Plates on side of tank QTY (4)
Top Mount Rupture Basin
ULC-S601 Canadian
Vent Extensions Optional

 


TRAILER

Generator Trailer 

Construction Formed Steel
Bed Size 77” x 35”
Finish Powder coat texture black
Suspension Single 3.5K Torsion Suspension CSA Certified
Wheels ST205/75R15
Rims White
Nitrogen Filled Yes
Connection 4 Pin
Coupler 5-Position adjustable 2” ball
Jack Pipe-mount swivel tongue jack
Plate Mount Included
Fenders Polycarbonate fenders
Warranty 4 Years

 


RATING DEFINITIONS

 

Standby - Applicable for a varying emergency load for the duration of a utility power outage with no overload capability.

Prime - Applicable for supplying power to a varying load in lieu of utility for an unlimited amount of running time. A 10% overload capacity is available for 1 out of every 12 hours.