{"id":8416706049,"title":"200 Amp Automatic Transfer Switch | ASCO 185 | NEMA 3 120\/240 Volts","handle":"200-amp-ats","description":"\u003ch1\u003e\u003cstrong\u003eProtect your home, business, and peace of mind with the ASCO series 185 Automatic Transfer Switch. \u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch4\u003e\n\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eASCO 300 SERIES \u0026amp; 3 PHASE SWITCH OPTIONS AVAILABLE!  \u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eCALL TO INQUIRE\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003ch3\u003eWhy should you choose an ASCO Automatic Power Transfer Switch?\u003c\/h3\u003e\n\u003cp\u003eCustomer service, rock-solid dependability, and the industry’s highest performance have made ASCO the first choice in emergency power for more than 80 years. Our power transfer switches are used in more emergency power backup systems worldwide than any other. ASCO is the name behind most of the technological advances in transfer switch design, and we have more patents than all other manufacturers combined. ASCO transfer switches are the first choice for installations of every kind, from homes and small businesses to the largest financial data centers and hospitals in the world.\u003c\/p\u003e\n\u003ch3\u003ePerformance sets the series 185 apart\u003c\/h3\u003e\n\u003cp\u003eThe Series 185 Automatic Transfer Switch incorporates the latest technology developed by ASCO for dependable operation in any environment\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhen utility power fails for just 1 second or more, the Series 185 Automatic Transfer Switch signals the generator to start\u003c\/li\u003e\n\u003cli\u003eIn less than 30 seconds your electrical power is normally restored\u003c\/li\u003e\n\u003cli\u003eOnce the Serie S 185 Automatic Transfer Switch senses utility power has reached an acceptable voltage level for a period of time, it automatically reconnects your power\u003c\/li\u003e\n\u003cli\u003eIt then smoothly shuts the generator down after an adjustable 2 - 5-minute cool-down period to extend generator life\u003c\/li\u003e\n\u003cli\u003eThe user-friendly control panel also allows you to manually run a test at the push of a button\u003c\/li\u003e\n\u003cli\u003eLED indicators to let you know the availability of both power sources and transfer switch positions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"How To Connect a Transfer Switch\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1262\/8579\/files\/TypicalSetupATS.png?v=1478602859\" style=\"display: block; margin-left: auto; margin-right: auto; float: none;\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003eASCO Series 185 Residential\/Light Commercial Automatic Transfer Switches\u003cbr\u003e\u003cbr\u003eProduct Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUser-friendly control interface with intuitive symbols and visual indicators to inform operator of transfer switch and power source status\u003c\/li\u003e\n\u003cli\u003eListed to UL 1008 for optional standby systems, handling total system load including motors and all other electrical loads\u003c\/li\u003e\n\u003cli\u003ecUL Listed for Canadian Installations\u003c\/li\u003e\n\u003cli\u003eMeets Article 702, NFPA-70 National Electric Code (NEC) requirements\u003c\/li\u003e\n\u003cli\u003eNominal service voltage 240V 50\/60Hz, Single Phase, 3 wire AC systems\u003c\/li\u003e\n\u003cli\u003eAvailable in 100 through 400A ratings\u003c\/li\u003e\n\u003cli\u003e200A and 400A Service Entrance designs feature disconnect circuit breaker on normal source\u003c\/li\u003e\n\u003cli\u003eTrue double-throw contacts with inherent mechanical interlocking to prevent connection of generator and utility sources\u003c\/li\u003e\n\u003cli\u003eTerminals for convenient connection of neutral and ground conductors\u003c\/li\u003e\n\u003cli\u003eAvailable in NEMA Type 1 Indoor (steel) and Type 3R Outdoor (aluminum) enclosures, with hinged door design\u003c\/li\u003e\n\u003cli\u003eSuitable for controlling standby generators with 2-wire automatic starting circuits\u003c\/li\u003e\n\u003cli\u003eAvailable in manually operated version, up to 230A•Available from stock\u003c\/li\u003e\n\u003cli\u003e24-hour support, call 1-800-800-ASCO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTime Delays\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable 1 or 3-second time delay to override momentary normal source outages to delay transfer switch and engine starting signals\u003c\/li\u003e\n\u003cli\u003eTransfer to emergency time delay - fixed at 10 seconds\u003c\/li\u003e\n\u003cli\u003eRetransfer to normal time delay - fixed at 5 minutes\u003c\/li\u003e\n\u003cli\u003eAdjustable 2 or 5 minutes unloaded running time delay for emergency engine cooldown\u003c\/li\u003e\n\u003cli\u003eFour - second-time delay to ignore momentary voltage and frequency transients during initial Genset loading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional Accessories\u003c\/h4\u003e\n\u003ch5\u003eStrip Heater\u003c\/h5\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1262\/8579\/files\/asco_strip_heater_c9f57c12-dc4f-4dd7-895d-fcc2d46350aa_small.png?v=1478604268\" alt=\"ASCO Strip Heater\"\u003eA strip heater with a thermostat is recommended for extremely cold areas to prevent condensation and freezing of this condensation. An external 120-volt source is required\u003c\/p\u003e\n\u003ch4\u003eOrdering Information\u003c\/h4\u003e\n\u003ccenter\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1262\/8579\/files\/ASCO_Ordering_Infromation.png?v=1478604469\" alt=\"ASCO Ordering Information from Aurora Generators\"\u003e\u003c\/center\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eASCO Series 185 Residential Microprocessor Controller\u003c\/h4\u003e\n\u003ch5\u003eControl and Interface Panel ASCO Seris S 185 Microprocessor Controller\u003c\/h5\u003e\n\u003cp\u003eThe ASCO group 4 Microprocessor Controller is used with all sizes of the Series S 185 Power Transfer Switches. Includes as standard all of the voltage, frequency, control, timing, and connectivity functions required for most optional standby power applications. \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ccenter\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1262\/8579\/files\/ATS_Controller.png?v=1478605910\" alt=\"\"\u003e\u003c\/center\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eVoltage and Frequency Sensing\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable single phase sensing on normal source\u003c\/li\u003e\n\u003cli\u003eNormal source pickup voltage is adjustable to either 198 volts or 209 volts; drop-out is adjustable to four incremental settings, 154 volts, 176 volts, 187 volts, or 198 volts\u003c\/li\u003e\n\u003cli\u003eFrequency sensing on the emergency source. Pickup is 57 Hz (nom 60 Hz) or 48 Hz (nom 50 Hz), and dropout is 51 Hz (nom 60 Hz), and 43 Hz (nom 50 Hz)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eStandard Selectable Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEngine exerciser to automatically test backup generator each week - Includes control switch for testing with or without load\u003c\/li\u003e\n\u003cli\u003eSelective load disconnect, double - throw contact to operate at an adjustable 0 - 20-second adjustable time delay prior to transfer and reset 0 to 20 seconds after transfer\u003c\/li\u003e\n\u003cli\u003e60 Hz or 50 Hz selectable switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eRemote Control Feature\u003c\/h4\u003e\n\u003cp\u003eTerminal provisions for connecting\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemote test switch\u003c\/li\u003e\n\u003cli\u003eRemote test switch with automatic transfer\u003c\/li\u003e\n\u003cli\u003eRemote time delay bypass switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl and Interface Panel\u003c\/h4\u003e\n\u003cul\u003eUser - friendly control interface with intuitive symbols and visual indicators to inform operator of transfer switch and power source status\u003c\/ul\u003e\n\u003ccenter\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1262\/8579\/files\/ASCO_Series_185_Controller.png?v=1478659070\" alt=\"ASCO 185 Controller\"\u003e\u003c\/center\u003e\n\u003cp\u003es\u003c\/p\u003e\n\u003ch4\u003ePerformance Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e240 volt spacing per UL and CSA standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eMeets or exceeds the requirements of the following regulatory agencies:\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e• UL 1008\u003c\/div\u003e\n\u003cdiv\u003e• CSA C22.2 No. 178\u003c\/div\u003e\n\u003cdiv\u003e• IEC 60947-6-1\u003c\/div\u003e\n\u003cdiv\u003e• NFPA 110\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eMeets or exceeds the requirements for Electromagnetic Compatibility (EMC)\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e• IEC60947-6-1 and CISPR Radiated and Conducted Emissions\u003c\/div\u003e\n\u003cdiv\u003e• IEC61000-4-2 Electric Discharge\u003c\/div\u003e\n\u003cdiv\u003e• IEC61000-4-3 Electromagnetic Field Immunity\u003c\/div\u003e\n\u003cdiv\u003e• IEC61000-4-4 Electrical Fast Transients\u003c\/div\u003e\n\u003cdiv\u003e• IEC61000-4-5 Surge Immunity\u003c\/div\u003e\n\u003cdiv\u003e• IEC61000-4-6 Conducted Disturbances\u003c\/div\u003e\n\u003cdiv\u003e• FCC CFR 47 Part 15\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2016-11-08T22:15:00-05:00","created_at":"2016-11-07T19:57:52-05:00","vendor":"Aurora Generators","type":"Transfer Switch","tags":["Accessories","Accessories_Transfer Switches","asco","ats","Transfer Switch"],"price":131600,"price_min":131600,"price_max":131600,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":28348190657,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"185A2200F4M","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"200 Amp Automatic Transfer Switch | ASCO 185 | NEMA 3 120\/240 Volts","public_title":null,"options":["Default Title"],"price":131600,"weight":9979,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":"1,586"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/1262\/8579\/products\/ASCO_185_ATS.png?v=1478566676","\/\/cdn.shopify.com\/s\/files\/1\/1262\/8579\/products\/185Closed.png?v=1478566677","\/\/cdn.shopify.com\/s\/files\/1\/1262\/8579\/products\/ATS_Controller.png?v=1478605886"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/1262\/8579\/products\/ASCO_185_ATS.png?v=1478566676","options":["Title"],"content":"\u003ch1\u003e\u003cstrong\u003eProtect your home, business, and peace of mind with the ASCO series 185 Automatic Transfer Switch. \u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch4\u003e\n\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eASCO 300 SERIES \u0026amp; 3 PHASE SWITCH OPTIONS AVAILABLE!  \u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"color: #ff0000;\"\u003e\u003cstrong\u003eCALL TO INQUIRE\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/h4\u003e\n\u003ch3\u003eWhy should you choose an ASCO Automatic Power Transfer Switch?\u003c\/h3\u003e\n\u003cp\u003eCustomer service, rock-solid dependability, and the industry’s highest performance have made ASCO the first choice in emergency power for more than 80 years. Our power transfer switches are used in more emergency power backup systems worldwide than any other. ASCO is the name behind most of the technological advances in transfer switch design, and we have more patents than all other manufacturers combined. ASCO transfer switches are the first choice for installations of every kind, from homes and small businesses to the largest financial data centers and hospitals in the world.\u003c\/p\u003e\n\u003ch3\u003ePerformance sets the series 185 apart\u003c\/h3\u003e\n\u003cp\u003eThe Series 185 Automatic Transfer Switch incorporates the latest technology developed by ASCO for dependable operation in any environment\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWhen utility power fails for just 1 second or more, the Series 185 Automatic Transfer Switch signals the generator to start\u003c\/li\u003e\n\u003cli\u003eIn less than 30 seconds your electrical power is normally restored\u003c\/li\u003e\n\u003cli\u003eOnce the Serie S 185 Automatic Transfer Switch senses utility power has reached an acceptable voltage level for a period of time, it automatically reconnects your power\u003c\/li\u003e\n\u003cli\u003eIt then smoothly shuts the generator down after an adjustable 2 - 5-minute cool-down period to extend generator life\u003c\/li\u003e\n\u003cli\u003eThe user-friendly control panel also allows you to manually run a test at the push of a button\u003c\/li\u003e\n\u003cli\u003eLED indicators to let you know the availability of both power sources and transfer switch positions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"How To Connect a Transfer Switch\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1262\/8579\/files\/TypicalSetupATS.png?v=1478602859\" style=\"display: block; margin-left: auto; margin-right: auto; float: none;\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003c\/p\u003e\n\u003ch4 style=\"text-align: left;\"\u003eASCO Series 185 Residential\/Light Commercial Automatic Transfer Switches\u003cbr\u003e\u003cbr\u003eProduct Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUser-friendly control interface with intuitive symbols and visual indicators to inform operator of transfer switch and power source status\u003c\/li\u003e\n\u003cli\u003eListed to UL 1008 for optional standby systems, handling total system load including motors and all other electrical loads\u003c\/li\u003e\n\u003cli\u003ecUL Listed for Canadian Installations\u003c\/li\u003e\n\u003cli\u003eMeets Article 702, NFPA-70 National Electric Code (NEC) requirements\u003c\/li\u003e\n\u003cli\u003eNominal service voltage 240V 50\/60Hz, Single Phase, 3 wire AC systems\u003c\/li\u003e\n\u003cli\u003eAvailable in 100 through 400A ratings\u003c\/li\u003e\n\u003cli\u003e200A and 400A Service Entrance designs feature disconnect circuit breaker on normal source\u003c\/li\u003e\n\u003cli\u003eTrue double-throw contacts with inherent mechanical interlocking to prevent connection of generator and utility sources\u003c\/li\u003e\n\u003cli\u003eTerminals for convenient connection of neutral and ground conductors\u003c\/li\u003e\n\u003cli\u003eAvailable in NEMA Type 1 Indoor (steel) and Type 3R Outdoor (aluminum) enclosures, with hinged door design\u003c\/li\u003e\n\u003cli\u003eSuitable for controlling standby generators with 2-wire automatic starting circuits\u003c\/li\u003e\n\u003cli\u003eAvailable in manually operated version, up to 230A•Available from stock\u003c\/li\u003e\n\u003cli\u003e24-hour support, call 1-800-800-ASCO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTime Delays\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable 1 or 3-second time delay to override momentary normal source outages to delay transfer switch and engine starting signals\u003c\/li\u003e\n\u003cli\u003eTransfer to emergency time delay - fixed at 10 seconds\u003c\/li\u003e\n\u003cli\u003eRetransfer to normal time delay - fixed at 5 minutes\u003c\/li\u003e\n\u003cli\u003eAdjustable 2 or 5 minutes unloaded running time delay for emergency engine cooldown\u003c\/li\u003e\n\u003cli\u003eFour - second-time delay to ignore momentary voltage and frequency transients during initial Genset loading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional Accessories\u003c\/h4\u003e\n\u003ch5\u003eStrip Heater\u003c\/h5\u003e\n\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1262\/8579\/files\/asco_strip_heater_c9f57c12-dc4f-4dd7-895d-fcc2d46350aa_small.png?v=1478604268\" alt=\"ASCO Strip Heater\"\u003eA strip heater with a thermostat is recommended for extremely cold areas to prevent condensation and freezing of this condensation. An external 120-volt source is required\u003c\/p\u003e\n\u003ch4\u003eOrdering Information\u003c\/h4\u003e\n\u003ccenter\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1262\/8579\/files\/ASCO_Ordering_Infromation.png?v=1478604469\" alt=\"ASCO Ordering Information from Aurora Generators\"\u003e\u003c\/center\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eASCO Series 185 Residential Microprocessor Controller\u003c\/h4\u003e\n\u003ch5\u003eControl and Interface Panel ASCO Seris S 185 Microprocessor Controller\u003c\/h5\u003e\n\u003cp\u003eThe ASCO group 4 Microprocessor Controller is used with all sizes of the Series S 185 Power Transfer Switches. Includes as standard all of the voltage, frequency, control, timing, and connectivity functions required for most optional standby power applications. \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ccenter\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1262\/8579\/files\/ATS_Controller.png?v=1478605910\" alt=\"\"\u003e\u003c\/center\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eVoltage and Frequency Sensing\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable single phase sensing on normal source\u003c\/li\u003e\n\u003cli\u003eNormal source pickup voltage is adjustable to either 198 volts or 209 volts; drop-out is adjustable to four incremental settings, 154 volts, 176 volts, 187 volts, or 198 volts\u003c\/li\u003e\n\u003cli\u003eFrequency sensing on the emergency source. Pickup is 57 Hz (nom 60 Hz) or 48 Hz (nom 50 Hz), and dropout is 51 Hz (nom 60 Hz), and 43 Hz (nom 50 Hz)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eStandard Selectable Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEngine exerciser to automatically test backup generator each week - Includes control switch for testing with or without load\u003c\/li\u003e\n\u003cli\u003eSelective load disconnect, double - throw contact to operate at an adjustable 0 - 20-second adjustable time delay prior to transfer and reset 0 to 20 seconds after transfer\u003c\/li\u003e\n\u003cli\u003e60 Hz or 50 Hz selectable switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eRemote Control Feature\u003c\/h4\u003e\n\u003cp\u003eTerminal provisions for connecting\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemote test switch\u003c\/li\u003e\n\u003cli\u003eRemote test switch with automatic transfer\u003c\/li\u003e\n\u003cli\u003eRemote time delay bypass switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl and Interface Panel\u003c\/h4\u003e\n\u003cul\u003eUser - friendly control interface with intuitive symbols and visual indicators to inform operator of transfer switch and power source status\u003c\/ul\u003e\n\u003ccenter\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1262\/8579\/files\/ASCO_Series_185_Controller.png?v=1478659070\" alt=\"ASCO 185 Controller\"\u003e\u003c\/center\u003e\n\u003cp\u003es\u003c\/p\u003e\n\u003ch4\u003ePerformance Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e240 volt spacing per UL and CSA standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eMeets or exceeds the requirements of the following regulatory agencies:\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e• UL 1008\u003c\/div\u003e\n\u003cdiv\u003e• CSA C22.2 No. 178\u003c\/div\u003e\n\u003cdiv\u003e• IEC 60947-6-1\u003c\/div\u003e\n\u003cdiv\u003e• NFPA 110\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eMeets or exceeds the requirements for Electromagnetic Compatibility (EMC)\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cbr\u003e• IEC60947-6-1 and CISPR Radiated and Conducted Emissions\u003c\/div\u003e\n\u003cdiv\u003e• IEC61000-4-2 Electric Discharge\u003c\/div\u003e\n\u003cdiv\u003e• IEC61000-4-3 Electromagnetic Field Immunity\u003c\/div\u003e\n\u003cdiv\u003e• IEC61000-4-4 Electrical Fast Transients\u003c\/div\u003e\n\u003cdiv\u003e• IEC61000-4-5 Surge Immunity\u003c\/div\u003e\n\u003cdiv\u003e• IEC61000-4-6 Conducted Disturbances\u003c\/div\u003e\n\u003cdiv\u003e• FCC CFR 47 Part 15\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e"}

200 Amp Automatic Transfer Switch | ASCO 185 | NEMA 3 120/240 Volts

..
Product Description
$ 1,316.00 USD
Maximum quantity available reached.

Protect your home, business, and peace of mind with the ASCO series 185 Automatic Transfer Switch. 

ASCO 300 SERIES & 3 PHASE SWITCH OPTIONS AVAILABLE!  CALL TO INQUIRE

Why should you choose an ASCO Automatic Power Transfer Switch?

Customer service, rock-solid dependability, and the industry’s highest performance have made ASCO the first choice in emergency power for more than 80 years. Our power transfer switches are used in more emergency power backup systems worldwide than any other. ASCO is the name behind most of the technological advances in transfer switch design, and we have more patents than all other manufacturers combined. ASCO transfer switches are the first choice for installations of every kind, from homes and small businesses to the largest financial data centers and hospitals in the world.

Performance sets the series 185 apart

The Series 185 Automatic Transfer Switch incorporates the latest technology developed by ASCO for dependable operation in any environment

  • When utility power fails for just 1 second or more, the Series 185 Automatic Transfer Switch signals the generator to start
  • In less than 30 seconds your electrical power is normally restored
  • Once the Serie S 185 Automatic Transfer Switch senses utility power has reached an acceptable voltage level for a period of time, it automatically reconnects your power
  • It then smoothly shuts the generator down after an adjustable 2 - 5-minute cool-down period to extend generator life
  • The user-friendly control panel also allows you to manually run a test at the push of a button
  • LED indicators to let you know the availability of both power sources and transfer switch positions

How To Connect a Transfer Switch

 

ASCO Series 185 Residential/Light Commercial Automatic Transfer Switches

Product Features

  • User-friendly control interface with intuitive symbols and visual indicators to inform operator of transfer switch and power source status
  • Listed to UL 1008 for optional standby systems, handling total system load including motors and all other electrical loads
  • cUL Listed for Canadian Installations
  • Meets Article 702, NFPA-70 National Electric Code (NEC) requirements
  • Nominal service voltage 240V 50/60Hz, Single Phase, 3 wire AC systems
  • Available in 100 through 400A ratings
  • 200A and 400A Service Entrance designs feature disconnect circuit breaker on normal source
  • True double-throw contacts with inherent mechanical interlocking to prevent connection of generator and utility sources
  • Terminals for convenient connection of neutral and ground conductors
  • Available in NEMA Type 1 Indoor (steel) and Type 3R Outdoor (aluminum) enclosures, with hinged door design
  • Suitable for controlling standby generators with 2-wire automatic starting circuits
  • Available in manually operated version, up to 230A•Available from stock
  • 24-hour support, call 1-800-800-ASCO

Time Delays

  • Adjustable 1 or 3-second time delay to override momentary normal source outages to delay transfer switch and engine starting signals
  • Transfer to emergency time delay - fixed at 10 seconds
  • Retransfer to normal time delay - fixed at 5 minutes
  • Adjustable 2 or 5 minutes unloaded running time delay for emergency engine cooldown
  • Four - second-time delay to ignore momentary voltage and frequency transients during initial Genset loading

Optional Accessories

Strip Heater

ASCO Strip HeaterA strip heater with a thermostat is recommended for extremely cold areas to prevent condensation and freezing of this condensation. An external 120-volt source is required

Ordering Information

ASCO Ordering Information from Aurora Generators

 

ASCO Series 185 Residential Microprocessor Controller

Control and Interface Panel ASCO Seris S 185 Microprocessor Controller

The ASCO group 4 Microprocessor Controller is used with all sizes of the Series S 185 Power Transfer Switches. Includes as standard all of the voltage, frequency, control, timing, and connectivity functions required for most optional standby power applications. 

 

 

Voltage and Frequency Sensing

  • Adjustable single phase sensing on normal source
  • Normal source pickup voltage is adjustable to either 198 volts or 209 volts; drop-out is adjustable to four incremental settings, 154 volts, 176 volts, 187 volts, or 198 volts
  • Frequency sensing on the emergency source. Pickup is 57 Hz (nom 60 Hz) or 48 Hz (nom 50 Hz), and dropout is 51 Hz (nom 60 Hz), and 43 Hz (nom 50 Hz)

 

Standard Selectable Features

  • Engine exerciser to automatically test backup generator each week - Includes control switch for testing with or without load
  • Selective load disconnect, double - throw contact to operate at an adjustable 0 - 20-second adjustable time delay prior to transfer and reset 0 to 20 seconds after transfer
  • 60 Hz or 50 Hz selectable switch

Remote Control Feature

Terminal provisions for connecting

  • Remote test switch
  • Remote test switch with automatic transfer
  • Remote time delay bypass switch

Control and Interface Panel

    User - friendly control interface with intuitive symbols and visual indicators to inform operator of transfer switch and power source status
ASCO 185 Controller

s

Performance Features

  • 240 volt spacing per UL and CSA standards
  • Meets or exceeds the requirements of the following regulatory agencies:

    • UL 1008
    • CSA C22.2 No. 178
    • IEC 60947-6-1
    • NFPA 110

  • Meets or exceeds the requirements for Electromagnetic Compatibility (EMC)

    • IEC60947-6-1 and CISPR Radiated and Conducted Emissions
    • IEC61000-4-2 Electric Discharge
    • IEC61000-4-3 Electromagnetic Field Immunity
    • IEC61000-4-4 Electrical Fast Transients
    • IEC61000-4-5 Surge Immunity
    • IEC61000-4-6 Conducted Disturbances
    • FCC CFR 47 Part 15

 